Products

CZA (OH1), CZE (OH2) series process pump
DN:25~400mm Q:2600m³/h H:300m Design working temperature:CZA 90℃ CZE 250℃ Design work pressure:CZA 1.6MPa CZE 4.0MPa Application: cleaning liquid |
Monitoring instrument Standard configuration: ● Double-layer isolation sleeve pressure monitoring between layers-electric contact pressure gauge or pressure transmitter Optional: ●Second sealed box liquid level alarm chain-tuning fork switch ●Imported low liquid level alarm chain-tuning fork switch ●Inlet pressure monitoring-electric contact pressure gauge or pressure transmitter ● Bearing temperature monitoring-thermocouple |

CZG (OH3) series pipeline pump
DN: 25~400mm Q: up to 2600m³/h H: up to 300m Allowable working temperature: ≤230℃ Design working pressure: ≤4.0MPa Application: clean or liquid containing a small amount of non-ferromagnetic suspended particles |
Monitoring instrument Standard configuration: ●Interlayer pressure monitoring of double-layer isolation sleeve-electric contact pressure gauge or pressure transmitter Matching:●Import liquid level alarm-tuning fork switch ●Inlet pressure monitoring-electric contact pressure gauge or pressure transmitter ●Bearing temperature monitoring—thermocouple |

CZY, CMY series submerged pump
CZY series DN: 25~400mm Q: Up to 2600m³/h H: up to 300m Allowable working temperature: ≤250℃ Design working pressure: ≤4.0MPa |
CMY series DN: 40~200mm Q: Up to 800m³/h H: up to 1200m Allowable working temperature: ≤250℃ Design working pressure: ≤10.0MPa |
Monitoring instrument Standard configuration: ●Interlayer pressure monitoring of double-layer isolation sleeve-electric contact pressure gauge or pressure transmitter Matching:●Second sealed box liquid level alarm interlocking-tuning fork switch ●Temperature monitoring of sliding bearing—thermocouple |

CDS series double suction pump
DN: 150~300mm Q: Up to 2300m³/h H: up to 400m Design working temperature: ≤230℃ Design working pressure: ≤4.0MPa Application: cleaning liquid |
Monitoring instrument Standard configuration: ●Interlayer pressure monitoring of double-layer isolation sleeve-electric contact pressure gauge or pressure transmitter Matching: ●Second sealed box liquid level alarm interlocking-tuning fork switch ●Imported low liquid level alarm chain—tune fork switch ●Inlet pressure monitoring-electric contact pressure gauge or pressure transmitter ●Bearing temperature monitoring—thermocouple |

CSP series mixed flow pump
DN: 200~650mm Q: Up to 7000m³/h H: up to 30m Allowable working temperature: ≤230℃ Design working pressure: ≤2.0MPa Application: cleaning liquid |
Monitoring instrument Standard configuration: ●Interlayer pressure monitoring of double-layer isolation sleeve-electric contact pressure gauge or pressure transmitter Matching: ●Second sealed box liquid level alarm interlocking-tuning fork switch ●Imported low liquid level alarm chain—tune fork switch ●Inlet pressure monitoring-electric contact pressure gauge or pressure transmitter ●Bearing temperature monitoring—thermocouple |

CMTT series vertical barrel pump
DN: 25~200mm Q: Up to 800m³/h H: up to 1200m Design working temperature: ≤-200~150℃ Design working pressure: ≤10MPa Application: easy vaporization, easy polymerization and insufficient effective cavitation margin |
Monitoring instrument Standard configuration: ●Interlayer pressure monitoring of double-layer isolation sleeve—pressure gauge or pressure transmitter Matching: ●Nitrogen pressure monitoring of secondary sealed box—pressure switch or pressure gauge ●Import liquid level monitoring-tuning fork switch ●Temperature monitoring of sliding bearing—thermocouple |

CMC (BB4) series
DN: 40~200mm Q: Up to 800m³/h H: up to 1200m Design working temperature: ≤-40~120℃ Design working pressure: ≤5.0MPa Application: general dangerous cleaning liquid |
Monitoring instrument Standard configuration: ●Interlayer pressure monitoring of double-layer isolation sleeve-electric contact pressure gauge or pressure transmitter Matching: ●Secondary seal liquid level alarm interlocking-tuning fork switch ●Bearing temperature monitoring—thermocouple |

CMCS (BB5) series
DN: 40~200mm Q: Up to 800m³/h H: up to 1200m Allowable working temperature: -200~230℃ Design working pressure (import/export): 10~30MPa Applicable: high temperature or ultra low temperature liquid without solid particles |
Monitoring instrument Standard configuration: ●Interlayer pressure monitoring of double-layer isolation sleeve-electric contact pressure gauge or pressure transmitter Matching: ●Secondary seal liquid level alarm interlocking-tuning fork switch ● Rolling bearing temperature monitoring-thermocouple |

Factory Address: Beihai Industrial Park, Houmu Village, Yingchengzi Street, Ganjingzi District, Dalian City office (marketing): Room 404, No. 9 Chengren Street, Shahekou District, Dalian City (Yindu Building)